Electric Circulation Heating Systems
3 KW, 6 KW, 11.5 KW
|
| Part Number | Model | Volts | Watts | "A" | "B" | "C" | Inlet or Outlet | Amps Drawn |
|---|---|---|---|---|---|---|---|---|
| 3HHL | 3 KW | 240 | 3000 | 22" | 16 3/8" | 5 1/2" | 1" F.S.P.S. | 12.5 amp |
| 6HHL | 6 KW | 240 | 6000 | 27" | 21 3/8" | 5 1/2" | 1" F.S.P.S. | 25 amp |
| 11.5HHL | 11.5 KW | 240 | 11,500 | 29 1/2" | 24 3/4" | 4 3/4" | 1" M.S.P.S. | 47.9 amp |
UL Recognition #E90821 (N)
3KW heats 45 gallons per hour - 30° Rise
List Price below with High Limit Protection
| Part No. | System Part Name | List Price |
|---|---|---|
| 3HHL | 3 KW Heater | $290.00 |
| P | Little Giant Pump No. 006 | $145.00 |
| PK | Pump Installation Kit | $55.00 |
| Total System Price | $490.00 |
6KW heats 90 gallons per hour - 30° Rise
List Price below with High Limit Protection
| Part No. | System Part Name | List Price |
|---|---|---|
| 6HHL | 6 KW Heater | $290.00 |
| P | Little Giant Pump No. 006 | $145.00 |
| PK | Pump Installation Kit | $55.00 |
| Total System Price | $490.00 |
11.5KW heats 115 gallons per hour - 30° Rise
List Price below with High Limit Protection
| Part No. | System Part Name | List Price |
|---|---|---|
| 11.5HHL | 11.5 KW Heater | $450.00 |
| P | Little Giant Pump No. 006 | $145.00 |
| PK | Pump Installation Kit | $55.00 |
| Total System Price | $650.00 |
Note: The 11.5 KW Heater Requires a 48 Amp Resistive Rating Contactor
and a 24V Transformer to operate.
Model #R8246A Contactor [Part No. CONT] List Price $60.00
Model #AT140A 24V Transformer [Part No. TR] List Price $30.00
| Ground Fault Interupter | $105.00 |
|---|
The #3000 Automatic System (listed below) will provide low water protection.
For Low Water Protection without #3000 Automatic System, order Low Water Protection [Part No. LWP]
List Price $90.00
| System Components | Part No. | 6 KW Heater | Part No. | 11.5 KW Heater |
|---|---|---|---|---|
| Little Giant Circulation Heater with Hi Limit | 6HHL | $290.00 | 11.5 HHL | $450.00 |
| #006 Little Giant Pump | P | $145.00 | P | $145.00 |
| Pump Installation Kit | PK | $55.00 | PK | $55.00 |
| #3000 Automatic System | 3000 | $190.00 | 3000 | $190.00 |
| #172 Trip Lever Drain Overflow | 172 D.3 for 3' Baptistry 172 D.4 for 4' Baptistry | $75.00 | 172 D.3 for 3' Baptistry 172 D.4 for 4' Baptistry | $75.00 |
| Total | $755.00 | Total | $915.00 |
Gravity Circulation is only recommended for the 3 KW Little Giant Heater. Higher KW heaters recover hot water too fast for Gravity Circulation. In addition, the water is delivered into the Baptistry at a high temperature so that manual stirring is normally required to mix the water. Also, the heater's thermostat cycles the heating element on and off. This shortens the thermostat's life; and due to the off time lengthens the heating time. Lime, magnesium and other minerals are deposited more readily with Gravity Circulation. However, an advantage of this system is that the cost of the pump and its operational cost is eliminated.
Circulation of water through the heater by pump is the best type Baptistry Heating System. The Baptistry water is heated uniformly without manual stirring. Minerals are not deposited as quickly because of the lower water temperature.
Assemble and make up tightly the complete heater and parts as shown (except slip joint nuts). Locate the most accessible place around the Baptistry for installation. Drill a 2-1/8" diameter hole 4-1/2" up from the Baptistry floor. Smooth hole and install chrome faced inlet flush port, by loosening at slip joint nut. Apply clear RTV sealant under chrome flange. Remove any outside insulation so port rubber gasket fits against outside of fiberglass wall. Measure center to center distance exactly between inlet and outlet fittings. Locate and drill a 2-1/8" hole for top port using method stated above.
Assemble complete heating system onto installed ports. Important - Block under heater or pump to support weight - this prevents leakage of Baptistry wall fittings.
Heaters are shipped with special Installation Instructions regarding wiring, etc.
Be certain heater is turned off before draining Baptistry. Always fill Baptistry before turning heater on. Dry operation will burn out heating element, and cause failure of the pump.
Copyright © 2002-2007 Little Giant Manufacturing Co., Inc.